Sensitive analysis of simazine based on platinum nanoparticles on polyoxometalate/multi-walled carbon nanotubes
[ X ]
Tarih
2016
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Academic Press Inc Elsevier Science
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this report, a novel molecular imprinted voltammetric sensor based on glassy carbon electrode (GCE) modified with platinum nanoparticles (PtNPs) involved in a polyoxometalate (H3PW12O40, POM) functionalized multi -walled carbon nanotubes (MWCNs) sheets was prepared for the determination of simazine (SIM). The developed surfaces were characterized by using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) method. SIM imprinted GCE was prepared via electropolymerization process of 100 mM pyrrole as monomer in the presence of 0.1 M acetate buffer (pH 4.0) containing 25 mM SIM. The linearity range and the detection limit of the developed method were calculated as 1.0 x 10(-19)-5.0 x 10(-9) M and 2.0 x 10(-11) M, respectively. In addition, the voltammetric sensor was applied to wastewater samples. The stability and reproducibility of the voltammetric sensor were also reported. (C) 2016 Elsevier Inc. All rights reserved.
Açıklama
Anahtar Kelimeler
Molecular imprinted sensor, Simazine, Platinum nanoparticles, Polyoxometalate, Multi-walled carbon nanotubes
Kaynak
Journal of Colloid and Interface Science
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
470