Sensitive analysis of simazine based on platinum nanoparticles on polyoxometalate/multi-walled carbon nanotubes

[ X ]

Tarih

2016

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Academic Press Inc Elsevier Science

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

In this report, a novel molecular imprinted voltammetric sensor based on glassy carbon electrode (GCE) modified with platinum nanoparticles (PtNPs) involved in a polyoxometalate (H3PW12O40, POM) functionalized multi -walled carbon nanotubes (MWCNs) sheets was prepared for the determination of simazine (SIM). The developed surfaces were characterized by using scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) method. SIM imprinted GCE was prepared via electropolymerization process of 100 mM pyrrole as monomer in the presence of 0.1 M acetate buffer (pH 4.0) containing 25 mM SIM. The linearity range and the detection limit of the developed method were calculated as 1.0 x 10(-19)-5.0 x 10(-9) M and 2.0 x 10(-11) M, respectively. In addition, the voltammetric sensor was applied to wastewater samples. The stability and reproducibility of the voltammetric sensor were also reported. (C) 2016 Elsevier Inc. All rights reserved.

Açıklama

Anahtar Kelimeler

Molecular imprinted sensor, Simazine, Platinum nanoparticles, Polyoxometalate, Multi-walled carbon nanotubes

Kaynak

Journal of Colloid and Interface Science

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

470

Sayı

Künye