A comparative study of ozonation, iron coated zeolite catalyzed ozonation and granular activated carbon catalyzed ozonation of humic acid

dc.authoridGUMUS, Dilek/0000-0001-7665-3057
dc.contributor.authorGumus, Dilek
dc.contributor.authorAkbal, Feryal
dc.date.accessioned2025-03-23T19:41:52Z
dc.date.available2025-03-23T19:41:52Z
dc.date.issued2017
dc.departmentSinop Üniversitesi
dc.description.abstractThis study compares ozonation (O-3), iron coated zeolite catalyzed ozonation (ICZ-O-3) and granular activated carbon catalyzed ozonation (GAC-O-3) for removal of humic acid from an aqueous solution. The results were evaluated by the removal of DOC that specifies organic matter, UV254 absorbance, SUVA (Specific Ultraviolet Absorbance at 254 nm) and absorbance at 436 nm. When ozonation was used alone, DOC removal was 21.4% at an ozone concentration of 10 mg/L, pH 6.50 and oxidation time of 60 min. The results showed that the use of ICZ or GAC as a catalyst increased the decomposition of humic acid compared to ozonation alone. DOC removal efficiencies were 62% and 48.1% at pH 6.5, at a catalyst loading of 0.75 g/L, and oxidation time of 60 min for ICZ and GAC, respectively. The oxidation experiments were also carried out using <100 kDa and <50 kDa molecular size fractions of humic acid in the presence of ICZ or GAC. Catalytic ozonation also yielded better DOC and UV254 reduction in both <50 kDa and <100 kDa fractions of HA compared to ozonation. (C) 2017 Elsevier Ltd. All rights reserved.
dc.description.sponsorshipScientific Research Project of the Ondokuz Mayis University, Samsun, Turkey [PYO. MUH -1901.11,006]
dc.description.sponsorshipThis study was supported by the Scientific Research Project of the Ondokuz Mayis University, Samsun, Turkey under grant number of PYO. MUH -1901.11,006.
dc.identifier.doi10.1016/j.chemosphere.2017.01.106
dc.identifier.endpage231
dc.identifier.issn0045-6535
dc.identifier.issn1879-1298
dc.identifier.pmid28171838
dc.identifier.scopus2-s2.0-85011623944
dc.identifier.scopusqualityQ1
dc.identifier.startpage218
dc.identifier.urihttps://doi.org/10.1016/j.chemosphere.2017.01.106
dc.identifier.urihttps://hdl.handle.net/11486/6669
dc.identifier.volume174
dc.identifier.wosWOS:000397076000025
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofChemosphere
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250323
dc.subjectHumic acid
dc.subjectOzone
dc.subjectCatalytic ozonation
dc.subjectIron coated zeolite
dc.subjectGranular activated carbon
dc.titleA comparative study of ozonation, iron coated zeolite catalyzed ozonation and granular activated carbon catalyzed ozonation of humic acid