Real Time Heart Rate Detection Using Non-Contact Photoplethysmography Signals
dc.authorid | KAVSAOGLU, Ahmet Resit/0000-0002-4380-9075 | |
dc.authorid | BOZKURT, MEHMET RECEP/0000-0003-0673-4454 | |
dc.authorid | Polat, Kemal/0000-0003-1840-9958 | |
dc.contributor.author | Kavsaoglu, Ahmet Resit | |
dc.contributor.author | Polat, Kemal | |
dc.contributor.author | Bozkurt, Mehmet Recep | |
dc.date.accessioned | 2025-03-23T19:48:35Z | |
dc.date.available | 2025-03-23T19:48:35Z | |
dc.date.issued | 2014 | |
dc.department | Sinop Üniversitesi | |
dc.description | 22nd IEEE Signal Processing and Communications Applications Conference (SIU) -- APR 23-25, 2014 -- Karadeniz Teknik Univ, Trabzon, TURKEY | |
dc.description.abstract | Heart is contracted rhythmically so as to drive nutrients and oxygen necessary for life through our organs with blood arteries. The frequency for the rhythmic contraction of heart just as a pump is called heart rate (HR). Heart rate variation (HRV) is a measure of a fluctuation of time interval between heart beats. HRV is calculated considering electrodiagram (ECG) signals, arterial blood pressure signals or photoplethysmography (PPG) signals-derived time series of in-between heart beats. HRV is used as a significant indicator for the detection of healthiness and sickness state. Such pathological cases as high blood pressure, heart failure, and septic shock can be diagnosed using HRV. Therefore, accurate and rapid detection of HR is essential to correct diagnosis. In this study, real-time heart rate detection was derived from contactless PPG signals. PPG calling for contact with skin becomes useless in case of tissue scars or burns. In such cases, the use of contactless PPG is superior. Contactless PPG consists of a light source and a camera that senses reflection or transmittance of the light source. Camera images obtained were processed through an interface prepared in the MATLAB (TM) GUI setting, and real-time heart rate detection was carried out. | |
dc.description.sponsorship | IEEE,Karadeniz Tech Univ, Dept Comp Engn & Elect & Elect Engn | |
dc.identifier.endpage | 199 | |
dc.identifier.isbn | 978-1-4799-4874-1 | |
dc.identifier.issn | 2165-0608 | |
dc.identifier.scopus | 2-s2.0-84903772265 | |
dc.identifier.scopusquality | N/A | |
dc.identifier.startpage | 196 | |
dc.identifier.uri | https://hdl.handle.net/11486/7628 | |
dc.identifier.wos | WOS:000356351400029 | |
dc.identifier.wosquality | N/A | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | tr | |
dc.publisher | Ieee | |
dc.relation.ispartof | 2014 22nd Signal Processing and Communications Applications Conference (Siu) | |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.snmz | KA_WOS_20250323 | |
dc.subject | photoplethysmography (PPG) | |
dc.subject | heart rate | |
dc.subject | peak detection | |
dc.subject | contactless PPG | |
dc.title | Real Time Heart Rate Detection Using Non-Contact Photoplethysmography Signals | |
dc.type | Conference Object |