A sensitive voltammetric sensor for determination of Cd(II) in human plasma

dc.authoridAtar, Necip/0000-0001-8779-1412
dc.contributor.authorYola, Mehmet Lutfi
dc.contributor.authorEren, Tanju
dc.contributor.authorIlkimen, Halil
dc.contributor.authorAtar, Necip
dc.contributor.authorYenikaya, Cengiz
dc.date.accessioned2025-03-23T19:40:52Z
dc.date.available2025-03-23T19:40:52Z
dc.date.issued2014
dc.departmentSinop Üniversitesi
dc.description.abstractThe development of electrochemical sensors via surface modification has attracted considerable attention as a low-cost method to the sensitive detection of a variety of analytes. In addition, the surface modification of electrodes has been directed toward several goals, often involving electrode kinetics and chemical selectivity. In this study, we performed the electrochemical modification of glassy carbon (GC) electrode with 2-thiolbenzimidazole (2-TBI). The developed electrode was characterized by the reflection-absorption infrared spectroscopy (RAIRS), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). According to the RAIRS results, the binding type of the 2-TBI to glassy carbon electrode was through the etheric linkage. The working range of the developed electrode was also studied. In addition, the developed electrode was applied to human plasma samples for the determination of Cd(II). The linearity range of Cd(II) was obtained as 1.0 x 10(-11)-2.5 x 10(-10) M with the detection limit (S/N = 3) of 2.40 x 10(-12) M. (C) 2014 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.molliq.2014.04.025
dc.identifier.endpage64
dc.identifier.issn0167-7322
dc.identifier.issn1873-3166
dc.identifier.scopus2-s2.0-84901045245
dc.identifier.scopusqualityQ1
dc.identifier.startpage58
dc.identifier.urihttps://doi.org/10.1016/j.molliq.2014.04.025
dc.identifier.urihttps://hdl.handle.net/11486/6439
dc.identifier.volume197
dc.identifier.wosWOS:000340301900010
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Molecular Liquids
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250323
dc.subject2-Thiolbenzimidazole
dc.subjectCharacterization
dc.subjectGlassy carbon electrode
dc.subjectElectrochemical sensor
dc.subjectCd(II) ion detection
dc.titleA sensitive voltammetric sensor for determination of Cd(II) in human plasma
dc.typeArticle

Dosyalar