Electrochemically grafted etodolac film on glassy carbon for Pb(II) determination

dc.authoridUstundag, Zafer/0000-0002-5550-106X
dc.authoridAtar, Necip/0000-0001-8779-1412
dc.contributor.authorYola, Mehmet Lutfi
dc.contributor.authorAtar, Necip
dc.contributor.authorQureshi, Munewar Saeed
dc.contributor.authorUstundag, Zafer
dc.contributor.authorSolak, Ali Osman
dc.date.accessioned2025-03-23T19:37:54Z
dc.date.available2025-03-23T19:37:54Z
dc.date.issued2012
dc.departmentSinop Üniversitesi
dc.description.abstractThis study reports the electrochemical modification of glassy carbon (GC) surface with etodolac (ETO), the characterization of this ETO modified glassy carbon (ETO/GC) electrode and its electroanalytical application for the determination of Pb(II) ions. Binding type of the etodolac with the glassy carbon surface was investigated and found that it was through the etheric linkage revealed from the reflection-absorption infrared spectroscopy (RAIRS). The ETO/GC electrode was characterized by cyclic voltammetry (CV), reflection-adsorption IR spectroscopy, electrochemical impedance spectroscopy (EIS), X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The ETO/GC electrode was found to be suitable for selective determination of Pb(II) by adsorptive stripping voltammetry in the solutions of the mixture of heavy metal ions, such as Cu(II) and Cd(II) and showed high stability and reproducibility. The stability and the potential range of the ETO/GC electrode were also studied. The developed method was validated according to the ICH guideline and found to be linear, sensitive, selective, precise and accurate. The linearity range of Pb(II) was 5.0 x 10(-10) to 1.0 x 10(-8) M with the detection limit (S/N = 3) of 1.67 x 10(-10) M. The validated method was applied successfully for the determination of Pb(II) in real samples. (c) 2012 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.snb.2012.06.082
dc.identifier.endpage1215
dc.identifier.issn0925-4005
dc.identifier.scopus2-s2.0-84864277445
dc.identifier.scopusqualityQ1
dc.identifier.startpage1207
dc.identifier.urihttps://doi.org/10.1016/j.snb.2012.06.082
dc.identifier.urihttps://hdl.handle.net/11486/6044
dc.identifier.volume171
dc.identifier.wosWOS:000308572700160
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherElsevier Science Sa
dc.relation.ispartofSensors and Actuators B-Chemical
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250323
dc.subjectEtodolac
dc.subjectCharacterization
dc.subjectGlassy carbon electrode
dc.subjectElectrochemical sensor
dc.subjectPb(II) ion detection
dc.subjectAdsorptive stripping voltammetry
dc.titleElectrochemically grafted etodolac film on glassy carbon for Pb(II) determination
dc.typeArticle

Dosyalar