Preparation of Hydrophobic Monolithic Columns for Online Solid-phase Extraction Coupled with HPLC for the Determination of Trace Level Benzo[a]pyrene
dc.contributor.author | Corman, Mehmet Emin | |
dc.date.accessioned | 2025-03-23T19:12:16Z | |
dc.date.available | 2025-03-23T19:12:16Z | |
dc.date.issued | 2017 | |
dc.department | Sinop Üniversitesi | |
dc.description.abstract | Extraction of trace level persistent organic pollutants is an important issue in water samples. So in this work, p(HEMAPA) monolithic columns were developed as a novel kind of solid-phase extraction adsorbents, as well as p(HEMAPA) solid-phase extraction (SPE) adsorbent was coupled with high-performance liquid chromatography (HPLC) (p(HEMAPA-HPLC) for the determination of benzo[a]pyrene (BaP) on-line mode. After p(HEMAPA-HPLC) parameters including the injection volume, flow rate, and the sample volume had been optimized in detail, BaP separation procedures on the p(HEMAPA-HPLC) containing mobile phase, different amounts of BaP, and reusability were performed. Advantages of this procedure are low quantitation limits (0.05–1.0 ng/mL), short extraction time, low consumption of organic solvents, and ease of automation and operation of the whole analysis. The experimental results indicated that p(HEMAPA-HPLC) allowed for one-step BaPs extraction, clean-up and analytical determination under the optimal conditions. The reusability of BaPs from water samples was 99.7% with a negligible capacity decrease after ten adsorption–desorption cycles. The method detection limit (MDL), relative standard deviation (RSD) and recovery were obtained as 0.007 ng/mL, 0.26%, and 97.0%, respectively. It was concluded that p(HEMAPA) monolithic column coupled with HPLC was an excellent alternative for the routine analysis of BaPs at trace level. | |
dc.identifier.doi | 10.15671/HJBC.2017.147 | |
dc.identifier.endpage | 151 | |
dc.identifier.issn | 1303-5002 | |
dc.identifier.issn | 2687-475X | |
dc.identifier.issue | 2 | |
dc.identifier.startpage | 143 | |
dc.identifier.trdizinid | 286567 | |
dc.identifier.uri | https://doi.org/10.15671/HJBC.2017.147 | |
dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/286567 | |
dc.identifier.uri | https://hdl.handle.net/11486/3779 | |
dc.identifier.volume | 45 | |
dc.indekslendigikaynak | TR-Dizin | |
dc.institutionauthor | Corman, Mehmet Emin | |
dc.language.iso | en | |
dc.relation.ispartof | Hacettepe Journal of Biology and Chemistry | |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.snmz | KA_TR_20250323 | |
dc.subject | Kimya | |
dc.subject | Analitik | |
dc.subject | Kimya | |
dc.subject | Uygulamalı | |
dc.subject | Çevre Bilimleri | |
dc.subject | Mühendislik | |
dc.subject | Kimya | |
dc.title | Preparation of Hydrophobic Monolithic Columns for Online Solid-phase Extraction Coupled with HPLC for the Determination of Trace Level Benzo[a]pyrene | |
dc.type | Article |