Contamination Measurements of Patient’s Lead-Insulated Rooms After I- 131 and LU-177 PSMA Treatment via Sweeping Test

dc.contributor.authorHarman, Kubra
dc.contributor.authorDemırbay, Tuğba
dc.contributor.authorDemir, Mustafa
dc.date.accessioned2025-03-23T19:11:54Z
dc.date.available2025-03-23T19:11:54Z
dc.date.issued2018
dc.departmentSinop Üniversitesi
dc.description.abstractI-131 and Lu-177 PSMA radionuclides have been widely used in the field of nuclear medicine totreat thyroid cancer for many years. In this treatment, the patients whose dose rate measurements are less than3 mR/h are generally discharged from the lead-insulated rooms where they are hospitalized. The aim of ourstudy is to evaluate the contamination measurements of these rooms after I-131 and LU-177 PSMA treatmentand to ensure radiation safety. A sweeping test was carried out by using Whatman papers (10x10 cm2 in size)to take samples from designated areas of these rooms in which three patients were treated with Lu-177 PSMAand four patients were treated with the I-131 radionuclide. Whatman papers are placed inside different tubes toprevent external contamination. Afterward, counting procedure was taken to the tubes for one minute by usingthe gamma counter which has different calibration factors both for Lu-177 and I-131 radionuclides. For thebackground extraction, one-minute counting test was applied to one of the Whatman papers that were not usedfor sweeping and background value was then obtained. It was statistically understood that the highestcontamination rate was observed on the surface of toilet potteries in each room. As a result, ventilation of theroom, meticulous cleaning of contaminated areas and the sweeping test must be implemented in each roomwhere the patients are treated with radionuclides before the treatment of other patients.
dc.identifier.doi10.17776/csj.359939
dc.identifier.endpage438
dc.identifier.issn2587-2680
dc.identifier.issn2587-246X
dc.identifier.issue2
dc.identifier.startpage431
dc.identifier.trdizinid290064
dc.identifier.urihttps://doi.org/10.17776/csj.359939
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/290064
dc.identifier.urihttps://hdl.handle.net/11486/3696
dc.identifier.volume39
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.relation.ispartofCumhuriyet Science Journal
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_TR_20250323
dc.subjectRadyoloji
dc.subjectNükleer Tıp
dc.subjectTıbbi Görüntüleme
dc.subjectTıbbi Laboratuar Teknolojisi
dc.titleContamination Measurements of Patient’s Lead-Insulated Rooms After I- 131 and LU-177 PSMA Treatment via Sweeping Test