Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Colak, E." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    A study on radiation interaction parameters of boron carbide/zirconium boride composites
    (Springer Heidelberg, 2025) Turhan, M. F.; Tursucu, A.; Ogul, H.; Kacal, M. R.; Polat, H.; Colak, E.; Yurtcan, S.
    In this study, photon interaction parameters such as radiation protection efficiency (RPE), total mass attenuation coefficient (mu/rho), linear attenuation coefficients (mu), half value layers (HVL), tenth value layers (TVL), mean free paths (MFP), effective atomic numbers (Z(Eff)) and effective electron densities (N-Eff) were experimentally investigated for the BCZrB-0, BCZrB-10, BCZrB-20, BCZrB-30, BCZrB-40 and BCZrB-50 in the energy range from 59.5 keV to 1332.5 keV. In the experiment, HPGe detector and Am-241 (59.5 keV), Ba-133 (81 keV, 276.4 keV, 302.9 keV, 356 keV and 383.9 keV), Na-22 (511 keV and 1274.5 keV), Cs-137 (661.7 keV), and Co-60 (1173.2 keV and 1332.5 keV) radioactive point sources were used. Experimental results compared with results of the WinXCOM, GEANT4 simulation code and FLUKA simulation code. Energy absorption build-up factors (EABF) and exposure build-up factors (EBF) were calculated with G-P fitting method in the energy region 0.015 MeV <= E <= 15 MeV. Kerma relative to air values were investigated in the energy region 0.001 MeV <= E <= 20 MeV. Effective removal cross section, total macroscopic cross section and number of transmitted neutron values were defined for composites. The agreement between experimental and WinXCOM program, between experimental and GEANT 4 simulation codes and between experimental and FLUKA simulation codes of gamma-ray interaction parameters are < 5.1%, < 6.5% and < 5%, respectively. All of the results are compatible with each other and BCZrB-50 is a good gamma-ray radiation absorber in the studied composites and BCZrB-0 is the best neutron absorber in the studied composites.
  • [ X ]
    Öğe
    Allozymic variations in the genus dryomys (rodentia: gliridae) distributed in Turkey
    (Wiley-Blackwell Publishing, Inc, 2009) Bulut, S.; Yigit, N.; Colak, E.; Colak, R.; Cam, P.; Saygili, F.
    [No abstract available]

| Sinop Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kütüphane ve Dokümantasyon Daire Başkanlığı, Sinop, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim